244 Hv should be ok,


Date: Tue, 5 May 2015 20:49:24 +0800
Subject: Re: [MW:23209] RE: 23206] Failed SSC test
From: amirzakee@gmail.com
To: materials-welding@googlegroups.com; materials-welding@googlegroups.com

Hi Alan
Based on the same WPQT but conducted on different test coupon the highest hardness value is 244 on the HAZ side.
Do you reckon hardness is the issue?