Dear all,
I have and PWHT cycle of 600-640 Deg C for 2 Hrs followed by 687 Deg C for 8 Hrs.
will it make any difference in any of the properties of WM &/or BM if I change the sequence of PWHT cycle i.e.first cycle of PWHT for 687 for 8Hrs followed by 600-640 for 2 Hrs?
Material: LAS
regards,
JJ
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.