Hi
 
As per paradox law of hydraulics, the pressure directly proportional to elevation
 
So , if there is height diffrence between the pressure gauges, you will definitely will get an difference in readings.
 
You may refere the fundamentals of hydraulics


 
On Sun, Feb 27, 2011 at 6:38 PM, Raghuram Bathula <raghurambathula@gmail.com> wrote:
in simple term its the weight of fluid (e.g. for water it is 1bar aprx
for every 10m of column height)

you may refer    http://www.engineeringtoolbox.com/static-pressure-head-d_610.html


On Feb 26, 11:58 pm, "k.ilangkumaran ilangkumaran"
<k.ilangkuma...@yahoo.com> wrote:
> Dear experts,
>  
>                Could you explain me that why there is big difference pressures between two gauges installed while hydro testing? The first pressure gauge shows 3barg less than the one installed in 30meters above.
>  
> regards
> Ilan 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
Thanks & regards,

K.Babu
Singapore
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...