Saturday, February 26, 2011

Re: [MW:10020] Applicable code for Coal Fired Power Plant

yes some equipments might fall under Sec VIII and piping in B31.3

On Sat, Feb 26, 2011 at 7:23 AM, Endri Prasetyo <endri.prasetyo@gmail.com> wrote:
Dear Experts,

Please advise me, if we use ASME code only, is there any possibility that applicable code for power plant both internal boiler and external piping will refer to other code besides ASME section I and B31.1? For example ASME B31.3 or so on.

Thanks in advance.

Regards,
Endri

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...