[MW:5171] RE: 5170] welding Repair percentage

Dear Soliman,

 

% weld repair based on linear length will be calculated as follows: Total length (mm) of the weld radiographed against total length (mm) of repairs which will give you the % of repair in length wise. In this you need to calculate the length of each repair based on RT film.

 

The % of repair will be very low in length wise compared to joint wise. As you indicted, joint wise is more practical compared to length wise.

 

Regards,

 

L. Prabhu kumar,


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of mohamed soliman
Sent: Friday, May 14, 2010 3:35 PM
To: materials-welding@googlegroups.com
Subject: [MW:5170] welding Repair percentage

 


 

Hi to all,

 

We are building new booster station ,our contractor wanted to calculate the repair percentage of the welding based on the linear lenght .Alwyas this should be calculated by the joint wise .Can any one refere any international standard that state how to calculate this rate.Please note that the client specs did not specify any thing on that.

 

Please send me your thoughts ASAP.

 

Regards

Soliman



 

 




-------------------------------------------------------------------------------------------------------------------------------------------------------------------
DISCLAIMER: The information contained in this communication is intended solely for the use of the individual or 
entity to whom it is addressed and others authorized to receive it. It may contain confidential or legally privileged 
information. If you are not the intended recipient, you are hereby notified that any disclosure, copying, distribution 
or taking any action in reliance on the contents of this information is strictly prohibited and may be unlawful. If 
you have received this communication in error, please notify us immediately by responding to this email and then 
delete it from your system. Saipem India Projects Limited (SIPL) is neither liable for the proper and complete 
transmission of the information contained in this communication nor for any delay in its receipt. 
-------------------------------------------------------------------------------------------------------------------------------------------------------------------

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...