Dear Members,
Please provide a clarification on the following query.
One PQR is qualified with GTAW+SMAW, ER 70S-3+E7018-1 and impact tested at-46.
Impact testing is required for the job at -29 Deg.C. Can I use ER70S-2 instead of ER70S-3 ?.
As per ASME Sec.II C, ER 70S-3 supports up to -20 Deg C & ER 70S-2 Supports up to -30 Deg.C.
Is QW 404.12 applicable in this change?.
Thanks & Regards
Muhammed Ibrahim PK
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments: