No,
It applies to different group number within same P number, and not with different P numbers.
Any way why you are impact testing this combination (P1 # P8), what are your design conditions?
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Sukamal Naskar
Sent: Monday, August 24, 2009 9:19 AM
To: materials-welding@googlegroups.com
Subject: [MW:2996] Technical Query on ASME Sec-IX ( QW-403.5)
Dear All,
Good Morning !!!
I have a query on ASME SEC-IX ( 2007 ED, 08 ADD )
QW-403.5 (c ) , states that “ --------------- In addition, when base metals of two different P-Number Group Number combinations are qualified using a single test coupon, that coupon qualifies the welding of those two P-Number Group Numbers to themselves as well as to each other using the variables qualified.”
Query: If we qualify one PQR, with P-No. 1 Gr. No 2 to P-No.8 Gr.No.1 material using SMAW ( E 309MoL) process with impact testing on weld metal & both HAZ portion , does this PQR supports the following WPS combination of base metals , if all other welding variables are unchanged ?
(i) P-No. 1 Gr.No.2 to P-No. 1 Gr.No.2
(ii) P-No. 1 Gr.No.2 to P-No. 8 Gr.No.1
(iii) P-No. 8 Gr.No.1 to P-No. 8 Gr.No.1
Please give your comments,
Thanking you,
Regards,
--
Sukamal Naskar
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---
No comments:
Post a Comment