Sunday, August 23, 2009

[MW:2988] Re: A350 Gr P22 purging

Dear Friend,
Cr above 3% purging is very must.without purging u can't accept.

Thanks & Regards,

K.GANESAN
Quality Control
ISGEC / ISGEC John Thompson,
A-4 Sector-24 Noida-201301 (UP)
Tel. +91-120-2411175
Direct Tel. +91-120-2411175
Mobile : +91-9952166894

--- On Sat, 22/8/09, kambiz zamani <kambiz_zamani50@yahoo.com> wrote:

From: kambiz zamani <kambiz_zamani50@yahoo.com>
Subject: [MW:2985] A350 Gr P22 purging
To: materials-welding@googlegroups.com
Date: Saturday, 22 August, 2009, 12:42 PM

Dear All , i want to know that A350 Gr P22 required to argon back purging (GTAW process) or not?                           regards ,k zamani IRICO. cswip3.1 welding inspector



See the Web's breaking stories, chosen by people like you. Check out Yahoo! Buzz
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone