Dear Balasubramanian,
Sorry,I have sent design temprs wronge…..
The actual design conditions as below,
Tubeside: -104/65 Deg C
Shell side: 120 deg c.
Materils:SS 304 flange (Heat exchanger Equipment body flanges)
Bolt & nut : A 320 gr L7 and A194 Gr b4,(M 30)
Please Advice me is it acceptable..
sorry fo asking help with wronge data.
Regards,
Prakash K B,
Process Engineer.
On 8/25/09, Balasubramanian Jawahar <jawaharcb@yahoo.com> wrote:
Dear Prakash,
Your Design Temperature does not show that your service is low temperature.Then why you need LTCS bolts?Any datas missing?...
Jawahar...
B.JAWAHAR, PETROFAC INTERNATIONAL LTD, SHARJAH,UAE.
--- On Tue, 8/25/09, prakash kamathuru <prakashkbp@gmail.com> wrote:
> From: prakash kamathuru <prakashkbp@gmail.com>
> Subject: [MW:3009] LTCS bolting for SS flange
> To: materials-welding@googlegroups.com
> Date: Tuesday, August 25, 2009, 11:10 AM
> Dear all,
>
> Can any one help me to get information regarding LTCS
> boltings used for SS flsangs.
>
> Presently we r using LTCS boltings A 320 Gr L7 for SS
> 304 Heat exchenger bonnet(head) flanges.Is there any effect
> on the equipment.
>
> Please give me some backup hint to get understand abt
> it.
>
> Design tempr is 300 deg C
>
> Regards,
>
> Prakash
>
> >
>
>
>
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---