Dear all friends
if flanges used for joining, that this joint will be used in hot service(hot media folw in pipe).due to gradiant temperature between inner surface of flange & bolt,it is likely that bolts yeilded and leakage is occured.
how can prevent it?
for hot & cold service, what variables must be considered for tightening( tensioning or torqueing) ?
regards.
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---