[MW:2977] bolt tightening

Dear all friends
if  flanges used for joining, that this joint will be used in hot service(hot media folw in pipe).due to gradiant temperature between inner surface of flange & bolt,it is likely that bolts yeilded and leakage is occured.
how can prevent it?
for hot & cold service, what variables must be considered for tightening( tensioning or torqueing) ?
regards.


--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material