If construction code does not require impact testing then yes
Στις Τετ, 21 Οκτ 2020, 17:12 ο χρήστης Manish Kumar <mkmkr431@gmail.com> έγραψε:
Dear Sir,--If P number of material 1 & group number 1 & 2 is mentioned in WPS.While supporting relevant PQR is P number 1 & group number only 2. In this case,Will WPS be valid for relevant PQR.Please advise us .Attachment-WPS & PQR--RegardsManish KumarInspection(Mechanical) EngineerPDIL-HURL Barauni site
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHfQ4k78r-LmTKgXVDyMf_9wE9PtMAo_C8QBbsd6aqpTaHWgwg%40mail.gmail.com.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAPOi40Bb0%3De%2B%3D0joikXSCbr4RVZKqhG6zjoyB9FDs6vheLdXKw%40mail.gmail.com.