shanmugam
API 653 the patch plate thickness is same as the plate thickness
Regards,
KISHOR
QC INSPECTOR
On Mon, Mar 2, 2020 at 10:02 AM shanmugam .N <nss2410@gmail.com> wrote:
--Dear Experts,Construction Code: API 653Annular PlateThickness: 13.5mmBottom plate thickness:8.0mmWe are in a position to weld "Patch Plate" on the Annular ring plates.All the repairs are not in the critical zone (3"inch as per API 653). As per API 653 the patch plate thickness within the critical zone is 1/4" maximum. I could not get any reference for the patch plate thickness beyond the critical zone and within the annular ring plate.Please kindly give your inputs with code reference.
With Regards,
N.S
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAMaJw0%2Bfd%3Dc0uZ540d15RP80%2Bu3fRDDmiY5Vg9U3gY8e8zY7jA%40mail.gmail.com.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAPd%2B2RQ1ywpAzqQ-z81_MzFacJ7Rp_833YhbKRjtB3wM2p2Gcg%40mail.gmail.com.