This means if your shell is in sections, then the longitudinal weldings in all the sections should not be in the same line.
Regards
N. S. Pandit
On Thu, 22 Oct 2020, 10:05 Rajeev Shukla, <gkpshuklaji@gmail.com> wrote:
SirI need to under stand the meaning of this line , and which code I should refer for Compressor received welding.Longitudinal seam in adjacent sections shall not be in same line.--On Saturday, 21 April 2018 at 11:57:35 UTC+5:30 joykol...@gmail.com wrote:Dear Expert,Please suggest Dia range.for WPS as per API 1104.--