Lseam of 2 shell shall not be in line, it shall be kept at 5XThickness of shell in staggered position
All code and std are specifying the requirement, check in section 8
THANKS & BEST REGARDS,
KG.PANDITHAN, BE, IWE, CSWIP 3.1,
ISO 9712 Level 2 in VT,
ASNT-Level II in PT,MT,RT & UT,
LA ISO 9001-2015,
International Welding Engineer.
CONSULTANT-WELDING & QUALITY
Mobile no: +919940739349
On Thu, Oct 22, 2020 at 10:05 AM Rajeev Shukla <gkpshuklaji@gmail.com> wrote:
SirI need to under stand the meaning of this line , and which code I should refer for Compressor received welding.Longitudinal seam in adjacent sections shall not be in same line.--On Saturday, 21 April 2018 at 11:57:35 UTC+5:30 joykol...@gmail.com wrote:Dear Expert,Please suggest Dia range.for WPS as per API 1104.--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/c23d7c90-1f2b-4a58-ab4d-651cbde1c374n%40googlegroups.com.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAJzm4eOTbs-yyiE87PGKnBKdBoy41Kt-8kwO1n%3DOsec4MV7ncw%40mail.gmail.com.
No comments:
Post a Comment