All six possible subjected to approved prequalified wps..
On Fri, 15 Mar 2019 at 8:31 PM, Kiran <karan.hbl@gmail.com> wrote:
Dear Experts,Please need your help regarding my queries as below as per AWS D1.1-2015.1) SMAW process is only applied to Material S275JR .2) S355JR & Gr I&II Fit up tack will be done by GMAE or FCAW.3) Gr I&II to S355JR welding not allowed.4) As per D1.1 welding in OH postion is not allowed.5) Gr I&II only GMAW is allowed.6) S275JR, S355 JR welding FCAW is allowed.above all comments received from our TPI Inspector can you please explain with clause as per AWS D1.1.Thanks and Regards--Kiran