No. Qualifications to be done to construction code.
On 7 Oct 2017 5:42 pm, "ABHISHEK SINGH" <mech.abhi17@gmail.com> wrote:
Dear Experts,
In my Job construction code is PD5500. Can I use Overlay PQR qualified as per ASME Sec. IX instead of EN15614-7??
Regards
Abhishek Singh
--