Tuesday, August 22, 2017

Re: [MW:26740] valve flow direction

Dear,
Gate valve is usually bidirectional. There may be problems with regard to,
1. The operating mechanism(if applicable)  like gear unit or actuator with face the other direction which may be problematic in terms of access and other nearby pipelines or means.
2. If hand operated the same issue of ease of operation.
3. Identifications like nameplate usually on front side. So affects ease of identification.

Functionally there is no problem.


On Tuesday, August 22, 2017, 7:58:23 AM GMT+5:30, Rameez khan RK <rk.rameezkhan21@gmail.com> wrote:


Dear Expat,
                       I have a question regarding gate valve flow direction. if the direction change during fit up then what type of problem facing can any one tell me regarding this issue. 



Thanking you

Rameez khan 

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...