Monday, August 14, 2017

Re: [MW:26714] Leak Test-reg

Helium leak test is best 

Regards 
Venkatesan 

On 6 Jul 2017 8:51 a.m., "Kannayeram Gnanapandithan" <kgpandithan@gmail.com> wrote:
what is best method to find leak in Studded Tubes other than Hydro-static test.
.
THANKS & BEST REGARDS,
KG.PANDITHAN, IWE,  AWS-CWI, CSWIP 3.1,
CONSULTANT-WELDING & QUALITY
Mobile no: +919940739349

--