Tuesday, August 22, 2017

Re: [MW:26739] valve flow direction

Hello Rameez,
Only in case of a gate valve, direction of flow is not important I suppose. It is an on-off type of valve.
Globe, Needle, Butterfly and Check valves have a control function which makes their connections direction specific.
 
Best Regards,
Shashank C Vagal 

 


On Tuesday, 22 August 2017 7:58 AM, Rameez khan RK <rk.rameezkhan21@gmail.com> wrote:


Dear Expat,
                       I have a question regarding gate valve flow direction. if the direction change during fit up then what type of problem facing can any one tell me regarding this issue. 



Thanking you

Rameez khan 
--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.


No comments:

Re: [MW:35507] WPS for Furnace PWHT

As per ASME B31.3, Clause 331.1.6 (b): Any required PWHT shall be carried out in accordance with the qualified WPS. For furnace PWHT inv...