Tuesday, August 22, 2017

Re: [MW:26739] valve flow direction

Hello Rameez,
Only in case of a gate valve, direction of flow is not important I suppose. It is an on-off type of valve.
Globe, Needle, Butterfly and Check valves have a control function which makes their connections direction specific.
 
Best Regards,
Shashank C Vagal 

 


On Tuesday, 22 August 2017 7:58 AM, Rameez khan RK <rk.rameezkhan21@gmail.com> wrote:


Dear Expat,
                       I have a question regarding gate valve flow direction. if the direction change during fit up then what type of problem facing can any one tell me regarding this issue. 



Thanking you

Rameez khan 
--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.


No comments:

[MW:35725] Dismillar material Welding

Dear experts,  In my Hydro Electric Project  materials using A517Gr.F and A537CL-II.  For A517Gr.F using E 11018M and A537CL-II using E 9018...