If the ultimate design strength is within 60ksi you can use it. Normally in structural welding using root and hot with 6013 and others with 7018. No code saying don't use such matters. Like don't use 6013 or should use only 7018 except particular company standard.
Wth regards
Maharaja Elavarasan
Welding inspector
Cswip 3.1
ASNT LEVEL II ( PT, MT, RT, UT, VT, RTFI)
Internal auditor iso 9001:2008
Wth regards
Maharaja Elavarasan
Welding inspector
Cswip 3.1
ASNT LEVEL II ( PT, MT, RT, UT, VT, RTFI)
Internal auditor iso 9001:2008
From: TDK YOKESH
Sent: 30-11-2016 13:50
To: materials-welding@googlegroups.com
Subject: Re: [MW:25780] Limits of E6013 in pressure vessel (sec viii div 1)
E7018 (basic electrode ) is recommended as it satisfies the mechanical properties than E6013 . If the joint is not going to experience any mechanical load nor and NDT you can go for it . I am not sure if code says about the electrode to be used .
On 30 Nov 2016 3:26 p.m., "Prasad Rode" <purode333@gmail.com> wrote:
Dear sir,
In fabrication of pressure vessel from 10mm thk plate, would we allow to use E6013 electrode.
Is any where given in code of sec viii div 1, about limits of E6013, or only E7018 is allow.
Regards
Prasad Rode
--
http://www.linkedin.com/groups/MaterialsWelding- 122787?home=&gid=122787&trk= anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com .
To post to this group, send email to materials-welding@googlegroups.com .
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/ .4e2ec747-1d48-40dd-a8de- 522e133423bd%40googlegroups. com
For more options, visit https://groups.google.com/d/optout .
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAKT-Tup9uqvWa7aKd%3DfNLPgU1%2BeXUSEc3FumdnsqJjskzi339w%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment