Saturday, November 12, 2016

Re: [MW:25665] Prepare one WPS with two supporting PQR as per AWS D1.1

Manoj,

As per AWS D1.1 you can use prequalified WPS , to cover maximum thickness.


P.NEILASHKUMAR 
Sent from my iPad
MOB : 966 551094590
             +91 9952110791

On 12-Nov-2016, at 9:55 AM, Manoj John <manojacgnr@gmail.com> wrote:

Dear experts,

I have two PQR as  per AWS D1.1.   
Process - FCAW without backing single side welding.
Thickness - 12 mm and 20 mm.

Can I make one WPS with the supporting of two PQR to use maximum thicknees in production welding.

Thanks and Regards,

Manoj.


--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CACgUO5n1a56swBttsdnOJdHZvF40nx8OqvjBU7KJuEg4-bd54Q%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...