Tuesday, July 14, 2015

[MW:23156] Overlap of reinforcement pad with existing pipe circumferential Joint

Deal All,

I have a question about Overlapping of RF Pad With an Existing Weld Joint.

We have a situation where hot tapping (NPS 36) to be performed on existing NPS 60 hot flare header. The branch connection was specified as Stub On with Reinforcement Pad as per ASME B31.3. There was a note specified on the ISO drawing to verify the hot tap location before executing the job. The contractor (perhaps overlooked the ISO note) weld the NPS 36 branch pipe and when they were about to weld reinforcement pad, they notice the reinforcement pad overlap with existing pipe weld.


Now the contractor has proposed to reduce the reinforcement pas width to 60mm to avoid overlapping with existing weld. I need you opinion on this proposed solution. Can we accept it.

What can be other possible solution keeping in view the welding requirements.

Design Code : ASME B31.3
Pipe Material : ASTM A672
Design Temp. 180 deg C
Design Pressure : 3.5 kg /cm2 g
Corrosion Allowance : 3.2 mm
Header WT: 15.3 mm
Header size : 60 inch
Branch size : 36 inch

--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/COL402-EAS147FEC1E05A2795171B521DE79C0%40phx.gbl.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:34919] Welder qualification certificate

Dear All     anyone can share a format for welder certificate and card format        Thanks & Best Regards Saleem manhappulath Mob:+9665...