This is typical flow accelerated errosion my suggestion is to measure wall thickness on the all elbows. After that you can investigate about root cause of damage. Check operation process values.
iPhone'umdan gönderildi
iPhone'umdan gönderildi
Dear All, please support to investigate the crack of ecanomozer tube.as attached pictureType of tube- spirlly finned tubespiral material-sa-178atube dia meter-219.1mmtube material-106bMaximum design pressure-5800kpa--