[MW:23202] Interpretation of ASME B 31.3 Clause 331.1.3

Dear Experts,

What will be the thickness requirement for PWHT of Branch Weld(O-Let) and Support direct welded to the pipe.
ASME B 31.3 clause 331.1.3 says
When components are joined by welding, the thickness to be used in applying the heat treatment provisions of Table 331.1.1 shall be that of the thicker component measured at the
joint, except as follows:
a) (a) In the case of branch connections, metal (other than weld metal) added as reinforcement, whether an integral part of a branch fitting or attached as a reinforcing pad or saddle, shall not be considered in determining heat treatment requirements.

If i am adding reinforcement pad / Cradle support > 20mm thick directly welded to the run pipe, is it required PWHT regardless of material or service?


Heat treatment is required, however, when the thickness through the weld in any plane through the branch is greater than twice the minimum material thickness requiring heat treatment, even though the thickness of the components at the joint is less than the minimum thickness.

If i have a 20mm thick pipe and i am welding one O-let we have a weld size maximum 30 mm. Did i need PWHT on the case?  or if the weld size is 40 mm then only i need to do the PWHT?

 I am just confused to get the actual Pipe thickness required for PWHT for Branch Connection (Pipe-Pipe, Pipe - Olet) and also for support-pipe welding. I need this reagrdless of material and service.

Can you please clarify.
I will be helpful with your valuable comment.

--
Thanks & Regards
Biplab Pal
 
Information in this email and any attachments is confidential and intended solely for the use of the individual(s) to whom it is addressed or otherwise directed. Please note that any views or opinions presented in this email are solely those of the author and do not necessarily represent those of the Company. Finally, the recipient should check this email and any attachments for the presence of viruses. Myself accepts no liability for any damage caused by any virus transmitted by this email.
 

--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAFnzQg1%2BfeOMmcBi3W7FTMoEgEHNAHA68%2BYZOfNY7Sgot2ohhw%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...