Thursday, November 27, 2014

[MW:22381] Weld Overlay Cladding

Dear Friend 

I am using GMAW process for Weld Overlay on Carbon+Alloy 825 Cladded Plate.
During Cladding process edges of the Cladded Plate Alloy 825 is not fusing properly and during RT its indication Lack of Fusion.
The Feeler Wire Used as SFA 5.4 ER NiCrMo-3

Can any body help me what is the reason.

--
Israr Ahmed Noor Mohammed
+919930308261

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:35504] Re: Clarification on SS304 Pipe EFW and RF Pad Weld Alignment per ASME Standards