Wednesday, August 1, 2012

Re: [MW:15004] change in electrode class

Pankaj Kolhe,

If you followed the ASME code,the IS2062 need to be requalified in spite that IS 2062 is nearer to ASTM A 36 . In another word, material IS 2062 can not be categorized into the same P No. as SA 516 Gr 70.
However,the E7018 has the same F No. as the E6018,,i.e. E6018 can be used without requalification.

hope this helps.

Regards,
Devin.

2012/8/1 <pankaj.kolhe@wipro.com>

Dear all,

If the procedure is qualified on E7018 Electrode for SA 516 Gr 70 then can we use this WPS/PQR for welding IS2062 Gr B by E6013 electrode. Also for welder qualification can we use this WPS/PQR , Give code reference

I think change in filler metal class is essential variable.

 

With Regards,

Pankaj Kolhe

QC

Wipro Water (Wipro Ltd)

O- + 91 22 39302135

M: +91 9323940892

 

Wipro Limited.Serene Properties Private Limited,Special Economic Zone,3rd Floor,Building No. 7, Plot No.3,TTC Industrial Area,Thane Belapur Road,Opposite Airoli Rilway station.Airoli, Navi Mumbai- 400708,Maharashtra

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
修延飞
Yanfei Xiu
技术中心 焊接室
Tech Center,welding department
山东核电设备制造有限公司
SNPEMC  
地址:中国山东海阳临港产业区
Address:Lingang Industrial Area,Haiyang City,Shandong Province ,PRC
TEL:15967615395


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...