Saturday, February 18, 2012

Re: [MW:13730] IQI Selection

You can claim only one concession.
Code clearly says OR and not AND.

On 2/15/12, Siva Kumar <mailmrsiva@yahoo.com> wrote:
> Dear All,
>
> As per ASME SEC-V, ART -2,T-276.2, for IQI selection, it has been mentioned
> that the weld reinforcement as per the referencing code can be added with
> nominal wall thickness of the pipe.
>
> As per B31.3, the acceptance for weld reinforcement or internal
> protrusion for wall thickness above 6mm to 13mm is 3mm.
>
> If we take a 4" sch std pipe, thickness of which is 6.02mm, Can we take into
> consideration 6.02mm + 3mm for reinforcement + 3mm for internal protrusion -
> total 12.02mm as nominal wall thickness for the essential wire to be visible
> as per Table T276 in Sec V art 2?
>
> If so, is there any reference that internal protrusion can also be
> considered?
>
> Please suggest.
>
> Siva.
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to
> materials-welding+unsubscribe@googlegroups.com
> For more options, visit this group's bolg at
> http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and
> meant for educational purposes only, Users must take their own decisions
> w.r.t. applicable code/standard/contract documents.
>

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...