[MW:13695] Re: Ice formation on freon lines at damaged/uninsulated sections

What is the material of the lines?
The carbon steel, loss its ductility when temperature goes below the
subzero tempe.
You can get the actual value of the temperature, then test the
material for impact value at this temp.
I hope you can get the required impact value for the pipe line
application from your design department.
If the values are not satisfactory, u can convience ur management,

regards
Sandeep Kumar

On Feb 14, 10:34 am, ags 36681 <ags1...@gmail.com> wrote:
> Dear friends,
> In our plant especially in refrigeration unit, so many lines (CS) or
> valves have failed insulation, say maintenance did some work on it and
> then not reinsulated, because of this, ice has formed on all over
> these uninsulated location.
>
> Some of the lines are in intermittent service (means alternate
> equipments are being used based on operation requirements, hence CUI
> is also expected),
>
> below doubts need your support to resolve.
> •How these locations will prone to premature failure. (Other than
> external corrosion).
> •Is there any brittle effect on material?
> •Kindly provide some good references to convince the management
> regarding the impact of this on equipments integrity.
>
> Regards,

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...