Re: [MW:13713] Interpass timing

Dear
Interpass means temperature (3" on either side of joint) inbtween two consecutive passes. And in this case if it is left after laying Root & Hotpass all through out the shit/night, then you tell me where is the essence of the word interpass.-Unless otherwise it has ben kept under the preheat you mentioned all through out the break.
 
As far as my knowledge goes, there is no code reference about this GEP(Good engineering practice). Basically this is a truely a welding-metallurgical aspect and if the joints are so critical, then your QC has right to say so.
Actually what happens: With only two passes laid on this XXS heavy wall thickness parent metal, the weld deposit thickness is not that much to withstand the contractional forces exerted by the parent metal from both side of the joint. Thereby resulting huge stress build up which leads to cracks. In heavy walled plates as well as pipes, longitudinal ( cold cracks / HIC ) on the bead laid yesterday are often seen in this partially welded items.
 
Way forward: May be at the best if you can put a deviation note and convince yourself as well the QC that it will be 100% NDT done before proceeding further. 100% LPI & 100% MPI on all such partially welded joints. And marking these joints with a distint identification no. and doing 100% RT of all these particular joints after final weld completion., even if the drg says % RT on all finished joints.
 
regards,
Debasish
Dubai. 
+971504349936 
 
 

On Wed, Feb 15, 2012 at 5:07 PM, jesti fer <jesti_fer@yahoo.com> wrote:
Dear experts,
I need your help, In our project (B.31.3) CS pipe joints ASTM A106 Gr.B 8" Sch XXS, our construction team kept the joints after root pass and hot pass welding, but our QC instructed to cut and and re-weld the joints. Really it is required and  it is mentioned any were in code? We are maintaining preheat at 150-Deg and inter pass temp 300-Deg
Please help me;;;;


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...