  Dear Experts,
  
   Recently, I met a problem that there has point defects in the fusion line in P92 weld seam.
   Only UT can find out the defect, but RT can not.
   When the welder repaired, we find nothing!
    What are the influence factors?   
    Let's discuss together!

   the pipe is 95mm thick. the electrode is Thermanit MTS 616, 4.0mm.
   How can I increase the penetration?
   What is the proper paramete?
     

 

   Best regards

 

    Roy 

No comments:

Re: [MW:35507] WPS for Furnace PWHT

As per ASME B31.3, Clause 331.1.6 (b): Any required PWHT shall be carried out in accordance with the qualified WPS. For furnace PWHT inv...