Tuesday, February 14, 2012

[MW:13677] Re: Blind thickness design

Dear Anish

The Blind flange is selected based on the dia of the nozzle nozzle,
hydro pressure.But if you dont know, use blind flange thickness
equivalent to attachment flange thickness(not neck thk).

Regards

Santhosh

On Feb 13, 10:22 pm, "anishdev" <anishd...@gmail.com> wrote:
> Dear all,
>
>                 Can someone help me to calculate the blind flange thickness
> for hydrostatic testing.
>
> Thanks and Regards
>
> Anish Dev.S
>
> Gulf East Engg
>
> Qatar

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35354] Cast-iron welding

1. Preheat joint area(other area, cover with mineral wool). 2. ENiCi or ENiFe-CI. 3. stringer bead. 4. peening is to be done on weldmetal im...