Use E/ER NiCrMo3 or ER NiCr3.
 
Thanks & Regards

J.Gerald Jayakumar
0091-9344954677
From: jaya anil <nethalaanil@gmail.com>
To: materials-welding@googlegroups.com
Sent: Monday, February 20, 2012 11:43 AM
Subject: [MW:13750] Re: welding of Monel (P40) E.Tee to SS Pipe(304)

Dear Experts,

Please let me know the Electrode or filler rod to be used to Qualify a
WPS for Monel(P40) to SS(P8) .I have to qulify a procedure for welding
this both at site.

regards
Anil Kumar

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.