Thanks, Manpreet and others, It was captured during RTFI and the lengths were 12 mm and 25 mm at 2 different locations. I have already given both as repair. But the contractor came with this table which shows Category M fluid, girth weld, weld imperfection ' Incomplete Pen' is referred to as B. On the following page, B refers to "depth" of IP to between ≤1mm and ≤ 0.2Tw (whichever is lower is implied) and not length. Now, that is one tough task to determine depth of an IP, by RT at least. In Cum Length, < 38 mm in 150 mm, we have acceptance. So, is my judgement correct or no? Best regards, Shashank Vagal --- On Tue, 21/2/12, manpreet <manpreetsin88@rediffmail.com> wrote:
|
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.