Dear Karandish,
Can u please give me following details.
- What is the Gas inlet & Outlet temp?
- What is Inside fluid temp inlet & Oulet of Bank?
- Clearance of Expansion of metal?
- Any Dwg.
Thanking You.
Regards
Sachin Shelar
Sr. Engineer - Process Engg
Thermax Ltd.
Ph +91 20 66126775/9766317515
E Mail: sachin.shelar1@thermaxindia.com
AA karandish <aa.karandish@yahoo.com> Sent by: materials-welding@googlegroups.com 09/15/2011 05:20 PM
|
|
Dear experts, In attached images you will find the failure happened on the junctions of header to heater tubes of a natural gas + steam heater. The heater specification is as follows: Inside fluid: natural gas + steam Outside fluid : flue gas from burning of natural gas in the reformer of an Ammonia plant. Tube and header material : SA-312 TP 3047H Considering the above let me have your suggestion regarding the failure reasoning. Regards, Karandish |
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.[attachment "IMG_1307.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1308.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1309.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1310.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1294.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1295.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1296.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1298.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1299.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1300.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1301.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1302.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1305.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax] [attachment "IMG_1306.jpg" deleted by Sachin Shelar/PROPOSAL/B&H/BnH_MAIL1/Thermax]
================================================================================================================
DISCLAIMER by THERMAX LIMITED
The information in this email is confidential and may be legally
privileged.It is intended solely for the addressee. Access to this email by anyone else is unauthorized.If you are not the intended recipient, any disclosure, copying, distribution or any action taken or omitted to be taken in reliance on it, is prohibited and may be unlawful. When addressed to our clients any opinions or advice contained in this email are subject to the terms and conditions.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment