Hi, In GMAW-Short circuit mode,There will be low heatinput,low voltage range and thust it leads to Lack of fusion(Side wall fusion) and it may not identify by RT. Thats why Code need to do Bend test for this particular transfer mode.Bend test clearly identify the lack of fusion. Thanks & Regards, (Karthik) Karthikeyan.S QA/QC Manager Getabec Energy Co.,Ltd. 379,Moo6,Soi8,Nikhomphatana, Rayong-21180, Thailand. Phone: 0066 38 897035-8 (Off) Fax: 0066 38 897034 Hand Phone: 0066 892512282 --- On Thu, 9/8/11, Prasu Cutie <pracuty@gmail.com> wrote:
|
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.