Sunday, September 4, 2011

Re: [MW:12341] ASME Section IX Welder Qualification

not possible to make wps.  pnos are essential for wps and welders(ferrous to non ferrous)
if u qualify welder with p1, he is qualified to weld pnos up to 15f provided other essentials are in order
kgp

On Fri, Sep 2, 2011 at 9:51 PM, vijay Katkar <katkar.vijay22@gmail.com> wrote:
Dear Kundan/Mayur,



ASME Section IX Welder Qualification related Question.



As mentioned in section IX for qualification of welder or welding
operator use qualified WPS with supporting PQR's, if our PQR is welded
with P No- 8 to P No-8 (SA 240 TP 316L TO SA 240 TP 316L).

Is it possible to make WPS with P No-1 to P no-1 (PQR is with P No -8
To P No-8)  but other than p no  all variable are same as used in PQR
(Like filler wire, shelding  gas, purging if require or etc), this WPS
will use only for welder qualification. please guide us.



Vijay Katkar

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...