When the assembly is being PWHT’ed, EM14K may be selected to maintain properties. This is especially the case where some of the assembly is either P4 or P5A and for which separate PWHT is not practical. In such a case, EM14K is a better choice than EM12K.
John
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of muthusrinivasan muthuselvam
Sent: Tuesday, January 25, 2011 3:16 AM
To: materials-welding@googlegroups.com
Subject: Re: [MW:9447] SAW filler for SA516 Gr70
F7A4 - EM12K it self sufficient. No need to go for High magnese EM 14K..
BR,
MSMS
On Sat, Jan 15, 2011 at 12:14 AM, rinshad abdul rahman <rinshad043@gmail.com> wrote:
Dear all,
Which is the suitable filler for SAW on SA 516 Gr70 (with PWHT) ?
EM12K or EM14K
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.