Hi, UCS-56 2 (c) 5 is for vessel under UW 2 (Lethal service) and it is only for CRO not for base metal. In your case your base metal thickness is 60mm(more than 32mm). if your vessel under UW2,you can do PWHT of vessel without CRO and do CRO after PWHT with Preheat as specified in UCS56 2 (c) 5.
Thanks & Regards,
(Karthik)
Karthikeyan.S QA/QC Manager Getabec Energy Co.,Ltd. 379,Moo6,Soi8,Nikhomphatana, Rayong-21180, Thailand. Phone: 0066 38 897035-8 (Off) Fax: 0066 38 897034 Hand Phone: 0066 892512282
--- On Wed, 1/5/11, rinshad abdul rahman <rinshad043@gmail.com> wrote:
From: rinshad abdul rahman <rinshad043@gmail.com> Subject: Re: [MW:9096] PWHT Requirement For CRO To: materials-welding@googlegroups.com Date: Wednesday, January 5, 2011, 6:06 PM
Dear sir, Thanks for your replay But what about the notes in UCS-56 2 (c) 5 that is if preheat (95 deg c) is there PWHT is not mandatory for thickness greater than 33mm On Wed, Jan 5, 2011 at 1:04 PM, Karthik <karthik6684@yahoo.com> wrote: Hi, Yes.You should do PWHT of SA516 with CRO as per ASME Sec,VIII,DIV 1,UCL34.Please find below the extraction. UCL 34 (a) Vessels or parts of vessels constructed of base material with corrosion resistant integral or weld metal overlay cladding or applied corrosion resistant lining material shall be postweld heat treated when the base material is required to be postweld heat treated. In applying these rules, the determining thickness shall be the thickness of the base material. When the thickness of the base material requires postweld heat treatment, it shall be performed after the application of corrosion resistant weld metal overlay cladding or applied corrosion resistant lining unless exempted by the Notes of Table UCS-56. (b) Vessels or parts of vessels constructed of chromium stainless steel integral or weld metal overlay cladding and those lined with chromium stainless steel applied linings shall be postweld heat treated in all thicknesses, except vessels that are integrally clad or lined with Type 405 or Type 410S and welded with an austenitic electrode or nonair- hardening nickel–chromium–iron electrode need not be postweld heat treated unless required by (a) above.
Thanks & Regards,
(Karthik)
Karthikeyan.S QA/QC Manager Getabec Energy Co.,Ltd. 379,Moo6,Soi8,Nikhomphatana, Rayong-21180, Thailand. Phone: 0066 38 897035-8 (Off) Fax: 0066 38 897034 Hand Phone: 0066 892512282
--- On Wed, 1/5/11, rinshad abdul rahman <rinshad043@gmail.com> wrote: From: rinshad abdul rahman <rinshad043@gmail.com> Subject: [MW:9091] PWHT Requirement For CRO To: materials-welding@googlegroups.com Date: Wednesday, January 5, 2011, 3:49 PM
Dear all,
I just want to know that whether PWHT is required for CRO on SA516 Gr. 70 (60 mm thick) on the same part we need do SMAW+SAW weld with 60 mm nominal size (construction is as per ASME BPV SEC VIII DIV 1)
-- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
|
-- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents. -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
|
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.