Tuesday, January 25, 2011

[MW:9457] Heat treatment in a Piping Joint as per ASME B31.3

Can anyone please clarify, whether heat treatment is required in a piping branch connection with joint thickness of 17 mm Header pipe with a connecting 22 mm thik weldolet(at joint).

As per Clause 328.5.4, i understood Heat treatment is not required.

Please Clarify.

Thanks in advance

Yoganandhan.P

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...