Wednesday, September 1, 2010

Re: [MW:6817] tests for PQR using R 308 LT1-5 flux cored filler rod

hi,
What is your construction code?( EN or ASME)
If EN code - You have to do as per EN15614.
If ASME - yo have to do as per ASME Sec.-IX -QW450

.

.Thanks & Regards,

 

(karthik)

Karthikeyan.S
QA/QC Manager
Getabec Energy Co.,Ltd.
379,Moo6,Soi8,Nikhomphatana,
Rayong-21180,
Thailand.
Phone: 0066 38 897035-8 (Off)
Fax: 0066 38 897034
Hand Phone: 0066 892512282


--- On Tue, 8/31/10, K.M Hrishikesan <hrishikm07@gmail.com> wrote:

From: K.M Hrishikesan <hrishikm07@gmail.com>
Subject: [MW:6806] tests for PQR using R 308 LT1-5 flux cored filler rod
To: "materials-welding" <materials-welding@googlegroups.com>
Date: Tuesday, August 31, 2010, 8:37 PM

Dear members
 
Can anybody suggest what are the special test requirements for performing PQR on a 6"dia, 8 mm thk. SS 304 pipe using TGX-308L flux cored filler rod for root run.
Subsequent passes are by conventional TIG wire followed by Arc welding.
 
Regards
Hrishi
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...