Tuesday, May 4, 2010

Re: [MW:5054] jetty pipeline RT inspection requirments

Hi.....yes the code is Asme B31.4/ .....some of our friend confirm that they used 10% RT for hydrocabons product and no test for waste water, fresh water ...
 
thanks
 
regards

On Tue, May 4, 2010 at 7:14 AM, B.Vaithiyanathan <pavainathan@gmail.com> wrote:
Hi,
       Let me know your design code whether ASME B 31.4/31.8 then only you can decide on extent of NDT.Since it's a modification work you can check with your client what was the design of code of existing line.
 
 
Regards,
Vaithiyanthan
QA Engineer,
WorleyParsons-Arabian industries
Oman

On Mon, May 3, 2010 at 4:39 PM, daniel iordache <daniel.iordache@gmail.com> wrote:
Hello,
 
Our client asked for a modification and implemetation for 4 new pipeline that will transfer products( goasoil, water, waste water) over the jetty to barge.....
 
Anyone that have a previous project like that can help me with procentage of inspection especiially for RT test ....?
 
regards
 


--
Daniel Iordache
Bureau Veritas - Angola
Mechanical& Welding Surveyor
Mobile Ao: +244921544583
Mobile Ro:   +40721731728
E-Mail:daniel.iordache@ao.bureauveritas.com
      daniel.iordache@gmail.com
         

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
With Best Regards

B.Vaithiyanathan

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
Daniel Iordache
Bureau Veritas - Angola
Mechanical& Welding Surveyor
Mobile Ao: +244921544583
Mobile Ro:   +40721731728
E-Mail:daniel.iordache@ao.bureauveritas.com
      daniel.iordache@gmail.com
         

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

1 comment:

Unknown said...

Hi,
Refer ASME B 31.8 Para 826 & 840.22
you will get the requirement of NDT extent.

Vaithiyanathan

[MW:34919] Welder qualification certificate

Dear All     anyone can share a format for welder certificate and card format        Thanks & Best Regards Saleem manhappulath Mob:+9665...