As per SSPC PA 2 the maximum thickness is 120%.
Regards
Hareesh K V
On 3/8/09, Jivan Dhamane <jivanadhamane@yahoo.co.in> wrote:
> Dear Mr. Hareesh
>
> Thank you very much for your reply, I know the minimum range of the
> acceptable DFT. As i do not have SSPC PA 2(Measurement of dry coating
> thickness with magnetic gauges) 5.2.1 &5.2.2. i asked especially for maximum
> DFT. And also i havent asked for minimum. If you can help me about maximum
> (only) DFT then it will be good for me. Hope i am clear now, and also u will
> reply soon.
>
> With Best Regards,
>
> Jivan Dhamane
>
> --- On Sun, 8/3/09, HAREESH K V <hareesh13h@gmail.com> wrote:
>
>
> From: HAREESH K V <hareesh13h@gmail.com>
> Subject: [MW:1718] Re: Please reply this mail
> To: materials-welding@googlegroups.com
> Date: Sunday, 8 March, 2009, 6:07 AM
>
>
>
> Dear Sir,
> For the %of DFT, Please refer SSPC PA 2(Measurement of dry coating
> thickness with magnetic gauges) 5.2.1 &5.2.2. In that 80% is the
> minimum acceptable area Otherwise it is a non confirmity area.
>
> Regards
>
> Hareesh K V
>
> --
> ----------------------
> Hareesh K V
> +91-9447625021
>
>
>
>
>
> Add more friends to your messenger and enjoy! Go to
> http://messenger.yahoo.com/invite/
> >
>
--
----------------------
Hareesh K V
+91-9447625021
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---
No comments: