[MW:1727] Re: Please reply this mail

Dear Friend,
 
        For all kind of NDT U CAN TAKE HELP BY ASME SECTION IX(QW-(302, 190)) &          ASME SECTION V(ARTICLE-5). I KNOW ONLY THIS. I THINK THIS WILL SOLVE UR PROBLEM.
 
REGARDS,
 

Ayaz Mehmood
Q.S (Mechanical)

Descon Engineering Fertil

Project(1320) Ruvais Abudhabi
Mob# +971501926232




From: Tirumala B N Tagore <tagore.tbn@gmail.com>
To: materials-welding@googlegroups.com
Sent: Sunday, March 8, 2009 7:56:11 PM
Subject: [MW:1724] Re: Please reply this mail

Dear Mr.Jivan,
Pneumatic testing of reinforcing pad is npt mandatory . But you need to see the purpose being served by the pad. If it is a pad to attach a structural part where no through opening is made, it is not required. However if there is a through opening and  such opening is being reinforced with a pad, you need to examine the weld integrity between the pad and the branching nozzle . Therefore it is a standrd practice to do pneumatic test of such pad and  you will be able to see the weld at Pad to Nozzle , Pad to mother pipe / veseel which is typically a fillet weld and  if  accessible , you also can see the weld of  branch nozzle to main pipe/ vessel examining at inside .
I beleive that underlying inetent of test is realised now.
WithBest Regards,
Tagore

On Sat, Mar 7, 2009 at 5:02 AM, <jivanadhamane@yahoo.co.in> wrote:
 

Dear Friends/Sir,

 

Mr. Bathula Raghuram, Rajeev Arora, Mukesh Kumar, Nilesh Patahre, Joshi, Muhhemad Ibrahim, Babu K

 

First of all sorry to disturb u, as i have seen you have sent answer of lot of queries from you people for that once again i am requesting u to reply the below queries. If my question is not correct then let me know means i will correct it.

 

 

Dear Friends (Dated :- 18/02/2009)

I would like to know whether Pneumatic Test of Reinforcement Pad for branch
connection of Process Piping is mandatory as per ASME B31.3. I searhed but I
could not found any paragraph in ASME B31.3.

Regards

Jivan Dhamane

 

 

Dear Friends ( Dated :- 03/03/2009)

 

I would like to know the maximum acceptable Dry Film Thickness of the paint in % or micron for a given DFT. As per my previous experience (where I worked) as per specification that was plus/minus 30% of the total paint DFT was accptable. But I couldn't found any code or standard documents related to the maximum acceptable dry film thickness of the paint.

 

If you have any code or standard then let me know the same means i can refer same. i need this information for piping job as well as tank job.

 

Regards

 

Jivan Dhamane 



Add more friends to your messenger and enjoy! Invite them now.



--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

Comments

Popular posts from this blog

Re: [MW:34105] SA266 GR4N 4 Cycle SPWHT

Hi,  You are correct, Minimum refers to the one cycle for which this part will expose until final work shop PWHT. hence mill test certificate shall include this.  Max. SPWHT, refers to additional cycles of heat treatment that are reserved for future repairs during equipment lifetime.  Again, these simulated no. Of cycles shall be specified in MTC.  The idea is we need to make sure that steel mechanical properties are not compromised upon exposure to multiple repairs (i e 4 cycles in your case).  One could say, if steel is subjected to 4 cycles and is ok, then it should by defacto be good for one cycle, yet, this is wrong assumption cause mechanical problems and microstructure of materials varies accordingly based on no. Of cycles for which material will expose. This is apparent in alloy steel and especially for impact test values as an example.  In your case, this forged CS with properties before PWHT can be understood to be " as forged" condition (i.e. Wit...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...