Do the 45 degree transverses scanning on the weld face if it is smooth alternatively do the 45 degree scanning within max 15 degree angle with weld axis. Do all the scanning in clockwise and anti clockwise direction.
Regards,
Bhaskar Kale
Bhaskar Kale
On 2/8/09, Ali Asghari <asghariali@rocketmail.com> wrote:
hiwhat is the suitable technique for detection chevron crack by ut or other ndt methods in thk>40?thanks adv
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/