Thursday, November 19, 2020

Re: [MW:31749] Norsok M-601

 If you deposit a cladding of 316 or 304 on a carbon steel, you may get hot cracking due to low Ferrite number. Therefore you deposit a layer of 309 which mixed with the carbon steel does not give hot cracking

Στις Δευ, 16 Νοε 2020, 16:38 ο χρήστης asghar...@gmail.com <asgharialigl@gmail.com> έγραψε:
Dear All.
Would you say what is the reason of this statement" When welding clad materials from both sides, the C and CMn steel shall be completely welded prior to welding the cladding. C or CMn steel or low alloyed steel weld metal shall not be deposited onto a high alloy base material or weld metal.'' ?
How is it possible for cladded piping?
Regards,

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4d8f2d92-d9ee-4ec7-89ca-ebdddd25d516n%40googlegroups.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAPOi40AuqmjYA5cN4ciu_swJ0i%3DHQ6TFJqPFQ5fOD7Z57XWUUw%40mail.gmail.com.

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...