Thursday, November 12, 2020

[MW:31734] Re: ph & Chloride Value for hydro test Water For Cs & SS Materials

Hello,

Here are our procedure, you may refer to it.

Test medium

Test medium shall be cleaned or potable fresh water or rust inhibitor. Note that chloride content in water shall be less than 250 ppm for carbon steel components and chloride content in water shall be less than 50 ppm for stainless steel components.

Regards

Bien ND


On Friday, November 6, 2020 at 10:34:02 AM UTC+7 Nandush Sreekumar wrote:
what is the Commonly Recommend ph & Chloride Value for  hydro test Water For Cs & SS Materials 









NANDUSH.S

QC INSPECTOR

MKG GLOBAL LLC

DUQM REFINERY PROJECT-OMAN

MOBILE:968-79614049

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/11313a0f-cc1f-4f96-ae15-0962329e34can%40googlegroups.com.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...