From where I get UCS-66 and UG-84?
On Thu 12 Nov, 2020, 9:15 AM Bien.ND |WIC, <bck055@gmail.com> wrote:
I agreed with Customer Care
Addition, I found problem in the PQR with actual test specimens that the subsize and reduction temperature not complied with UCS-66. You also check it out at UG-84.--On Tuesday, November 10, 2020 at 7:00:42 PM UTC+7 Shahil wrote:Hello everyone,Can anyone help me in finding out problems arising during impact toughness testing of the weld joint of the pressure vessel.Thank you,
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/1ad5e4df-0c79-4c0c-a88f-97248bf4aa9dn%40googlegroups.com.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CALfBO_9koO8XgipLLcsrRWRiwDKei-TSpWomFNVmQ7%2Bo128oGA%40mail.gmail.com.