MIT exempt per UCS-66 Curve 'D'
On Sat, May 26, 2018 at 11:15 PM, vishnudas balachandran <vishnudasb@gmail.com> wrote:
--Dear All,Vessel Data,MDMT = ( - 30 Deg C),Plate thickness = 12mm,Dished end = 12/14,Material = SA 516 Gr.70 N.+ HICDesign Code - ASME Sec VIII DIV 1.Is Impact testing required ?As per UG-20 (f) (3) ,"Design temperature is no warmer than 650°F (345°C) nor colder than −20°F (−29°C). Occasional operating temperatures colder than −20°F (−29°C) are acceptable when due to lower seasonal atmospheric temperature."Is there any provision for wave Impact testing as per code provision(s). Kindly advise.
--Regards,
Vishnu*Before printing, think about your ENVIRONMENTAL responsibility!Don't print unless necessary.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com .
Visit this group at https://groups.google.com/group/materials-welding .
For more options, visit https://groups.google.com/d/optout .
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.