Tuesday, May 8, 2018

Re: [MW:27807] Aluminum MIG Welding - failed PQR


2018-05-08 9:11 GMT+03:00 'c sridhar' via Materials & Welding <materials-welding@googlegroups.com>:
Your photos clearly shows endless amount pores in the weld

The main cause for porosity in aluminum is hydrogen, which       has very high solubility in molten aluminum but very low            solubility in solid. Hydrogen gas is therefore evolved as the weld   pool solidifies. If the cooling rate is too high, the gas remains in      the metal in the form of porosity. Thus, any compound containing hydrogen and contaminating the filler wire or work surface can cause porosity.

Oil, moisture or other contaminants may be present on the        filler wire. In addition, the oxide layer of aluminum tends to get    hydrated and improper cleaning of the oxide layer immediately preceding welding could be a cause for porosity. Ensuring that     the plate is clean before welding and switching to clean, high   quality electrodes will reduce the likelihood of forming porosity.

The amount of porosity depends on how fast the weld pool  solidifies. Increasing the welding current and/or decreasing          the travel speed will increase the heat input, and help retard the cooling rate allowing gases to escape from the weld pool and  thereby reducing the risk of porosity.

Filler wires should ideally be kept in their packaging until      needed; wire that is left out ion open workshop conditions will absorb moisture into its oxide layer. It is advisable when welding aluminum to wipe each wire prior to use with a clean cloth dipped in acetone.
Pre heat the weld and HAZ area to mimnimum150 deg. C to eliminate hydrogen pores. Once you overcome it, the tests
will pass through.
Sridhar.


On Monday, 7 May, 2018, 4:16:16 PM IST, Hani Al Masry <hanyonalfy@gmail.com> wrote:


Dear experts 

regarding A/M Subject kindly advice why the PQR Test had been failed two times even this WPS/PQR Approved before and we just tried to copy it 

all welders 2 times failed in root bend / tension some times not reach 250 MPA as required  (2 root bend + 2 root face + 2 tensile testing are required)

the lab said first time there are porosity
and inclusions but even 2nd test was failed  (attached photos for your reference) 

BASE METAL       :  AA 5083 H 321  
FILLER METAL       :  ER 5356  
Joint Preparation: -              Single V CPJ

Weld Layer

WELDING PROCESS

WELDING POSITION / DIRECTION

ELECTRODE(S)

GAS SHIELD

GAS FLOW RATE

lit/min.

AMPS

VOLTS

WELDING SPEED mm./min.

FLUX

WFS

M/Min.

Mode of Metal transfer for MAW

SIZE

mm

TRADE NAME

POLARITY

1

GMAW

3G

1.2

AUTO ROD 5356

DCEP

ARGON 99.99%

15-25

120-180

18-26

12-20

NA

8.5

Pulse transfer

2

GMAW

3G

1.2

AUTO ROD 5356

DCEP

ARGON 99.99%

15-25

120-180

18-26

120 - 140

NA

8.5

Pulse transfer

Back weld

GMAW

3G

1.2

AUTO ROD 5356

DCEP

ARGON 99.99%

15-25

120-180

18-26

100 - 110

NA

8.5

Pulse transfer









--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.



--
Dr. Georgios Dilintas,
Dipl. Ing. In Aeronautic and Space Engineering
Ph.D in Mechanics of Solids - Computational Mechanics
A.I.S, A.N.I, IRCA Lead Auditor
Welding, Stress Analysis, Corrosion, QA/QC, Failure Analysis, Risk Analysis

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...