Monday, May 21, 2018

Re: [MW:27869] minimum distance limitation between two weld joints

In ASME , 5Xthickness for shell course

On Mon, 21 May 2018 2:04 pm Jaydeep, <jaydip712@gmail.com> wrote:
Dear,

Please refer DIN EN 13480-4_2012-11, Clause 8.1

Longitudinal weld seam in adjoining components shall be staggered by twice the nominal wall thickness, with a minimum distance of 20 mm.

Thank you!!
Jaydeep Limbasiya
QA QC Engineer

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone